Magnetic flow meter yokogawa axf200 magnetic integral remote flowmeter. For details on the axfa14gc magnetic flowmeter converter, see the. Pdf yf100 250300should flowmeter yokogawa yf105 flowmeter yokogawa yf108 yf105 yf115 yf108 yf104 vortex flow converter yfa11 vortex flow meter yokogawa. Users manual axfa11g magnetic flowmeter remote converter. Browse magnetic flowmeter in the yokogawa field instrument division catalog including axfa14gc magnetic flow meter remote converter,axfa11 magnetic flow converter,admag axf magnetic flow meters,admag ca capacitance magnetic flowmeter,admag axw magne. It may be necessary to select a magnetic flowmeter that is larger or smaller than the adjacent piping to ensure the fluid velocity is in the specified measuring range of the sensor. Yokogawa axf040 axf magnetic flow meter integral remote. Users axf manual magnetic flowmeter integral flowmeter.
The admag axr is the worlds first twowire magnetic flow meter which employs the fluid noise free dual frequency excitation method, achieving excellent stability for instrumentation. Based on yokogawas decades long experience in magnetic flowmeters, the axf series continues the tradition of high quality and reliability that has become synonymous with the yokogawa name and in addition brings to the market an even higher level of performance and increased functionality. Magnetic flow meter yokogawa axf040 magnetic integral remote flowmeter. This is due to their flexibility, ruggedness in harsh environments, and varied functionality to handle anything from simple measurements to power quality analysis and pressure calibration. More than half a century has passed since yokogawa developed japans first magnetic flow meter for industrial use in 1955, and today, yokogawa s magnetic flow meters are widely used in a variety of applications thanks to features such as low pressure loss and maintenancefree operation due to no obstacles and moving parts in the fluid flowing. When moving the magnetic flowmeter, always use a trolley and have at least two people carry it. View and download yokogawa admag axf series user manual online. Admag total insight magnetic flowmeter yokogawa europe. It is often better to calculate the ideal meter size rather than simply match the existing pipe size. General introduction of yokogawa admag axg magnetic flowmeters axg100ga000ca1al212b1da2nchgrl. Our inventory includes everything from low flow magmeters to insertion magnetic flow meters and more, like our fmg90 series electro magnetic flow sensor for conductive liquid media, which does not contain any moving parts.
Based on foundation fieldbus specifications, axf fieldbus magnetic flow meter models offer more flexible instrumentation. Yokogawa introduced the worlds first vortex flow meter for industrial use in the 1960s, which is now widely used for measuring liquid, gas, and steam. Magnetic flow meter yokogawa axf200 axf remote flowtube. In line magmeters the in line type magnetic flow meters offer a higher accuracy. The dual frequency excitation method is a yokogawa innovation. When moving the magnetic flowmeter, always use a trolley and have at. According to this principle, when a conductive medium passes through a magnetic field b, a voltage e is generated which is proportional to the velocity v of the medium, the density of the magnetic field and the length of the conductor. Magnetic flowmeters can measure properly when the electrical conductivity of the liquid is greater than approximately 5. Users axf magnetic flowmeter integral flowmeter remote. Magnetic flow meter animation s bharadwaj reddy july 22, 2015 april 1, 2020 a magnetic flow meter mag meter, electromagnetic flow meter is a transducer that measures fluid flow by the voltage induced across the liquid by its flow through a magnetic field. Omegas fmg600 series in line flange and wafer style meters. The flow rate is counted one pulse at a time according to the setting of totalization pulse weights. Magnetic flow meter theory faradays law and the flow rate magmeters calculate fluid velocity v by measuring the induced voltage e on the electrodes q v a volumetric flow rate q is velocity v times crosssectional area a a v s e k b d v not effected by changes in fluid conductivity. Yokogawa admag axg magnetic flowmeters axg100ga000ca1al212b1da2nchgrl.
Yokogawa admag axg magnetic flowmeters axg100ga000ca1al212b. Be careful because using magnetic flowmeters on fluids with low conductivity, such as deionized water, boiler feed water, or hydrocarbons, can cause the flowmeter to turn off and measure zero flow. Incorporating both calibration factors k and q produces the desired practical equation for a flow metering device. Kobold offers a variety of flow sensors that can directly determine the flow rate of a gas or a liquid.
Available with hart, foundation fieldbus, or profibus pa, device diagnostics, and smart meter verification. If conditions are suitable for their use, magmeters produce. Principle of magnetic flow meter based on faradays law. The axf magnetic flow meter is a sophisticated product with outstanding reliability and ease of operation, developed on the basis of decades of field experience. Submersible sensor suitable for flooded chambers and pits buriable sensor. Mass flow calculation in digitalyewflo vortex flow meter. This will insure an appropriate liquid velocity for the application.
A magnetic field is applied to the metering tube, which results in a potential difference proportional to the flow velocity perpendicular to the flux lines. Based on foundation fieldbus specifications, axf fieldbus magnetic flow. A wide variety of yokogawa magnetic flowmeter options are available to you, there are 242 suppliers who sells yokogawa magnetic flowmeter on, mainly located in asia. Flow meter manuals, drawings, certifications, and other. Magnetic flowmeters yokogawa admag axg wiratama mitra. The admag axw series of magnetic flow meters has been developed based on yokogawas decadeslong experience in magnetic flowmeters. Download product documentation print product page add to request the axw series continues the tradition of high quality and reliability that has become synonymous with the yokogawa name. Admag ti series axg magnetic flowmeter installation. We also offer many models of flow transmitters that can both monitor and control flow. The yokogawa magnetic flow meter twowire magnetic flow meter can be installed in the twowire system without any ac power source, thus drastically reducing the initial instrumentation cost. Yokogawa axf040 axf magnetic flow meter integral remote flowtube.
Admag axr twowire magnetic flowmeters yokogawa europe. For replaceable electrodes for fluid temperatures of generalpurpose use and explosion proof type, 10c 14for less, please contact yokogawa office. Product data sheet january 2014 0081004727, rev ue industry leading performance with standard reference accuracy of 0. Yokogawa makes no warranty of any kind with regard to this material, including, but not limited to, implied warranties of merchantability and suitability for a particular purpose.
National association of corrosion engineers 1985 corrosion data survey. Browse magnetic flowmeter in the yokogawa field instrument division catalog including axfa14gc magnetic flow meter remote converter,axfa11 magnetic flow converter,admag axf magnetic flow meters,admag ca capacitance. Be careful that no damage is caused to personnel through accidentally dropping it, or by exerting excessive force on the magnetic flowmeter. Admag axf series measuring instruments pdf manual download. Shop at omega for the highest quality meters you need for your application, some models even qualify for quick shipping. Get the best deals on yokogawa flow meters when you shop the largest online selection at. Aem im 1e7b002e im 1e7b002e 14th edition yokoga wa electric corporation. Yokogawa axf125g magnetic flowmeters axf125g description yokogawa axf125g magnetic flowmeters axf125g yokogawa s magnetic flowmeter is supported by a long history of more than half a century. The admag axf is the magnetic flow meter which has adopted the proven dual frequency excitation. Depending on the application variables and media specifications, different flowmeters or flow monitors can be used. Magnetic flowmeter on yokogawa field instrument division. Yokogawa axf125g magnetic flowmeters axf125g description yokogawa axf125g magnetic flowmeters axf125g yokogawas magnetic flowmeter is supported by a long history of more than half a century. Foundation fieldbus communication type magnetic flowmeter.
The fmg600 magmeters have no moving parts and a ptfe lining, they can handle applications involving wastewater, pulp, food, and slurries. Users 3 series manual coriolis mass flow and density. Axf series magnetic flowmeter installation manual yokogawa. Electromagnetic flowmeters magmeters are among the most widely used flowmeter types today. Techtalkmagnetic flowmeter sizing clipper controls. Users 3 series manual coriolis mass flow and density meter. Our inventory includes everything from low flow magmeters to insertion magnetic flow meters and more, like our fmg90 series electromagnetic flow sensor for conductive liquid media, which does not contain any moving parts. This manual provides the basic guidelines for installation, wiring procedures and basic operation of admag ti total. The value q is the volumetric flow rate, a is the cross sectional area of the pipe, and v is the fluid velocity. Table of contents ai function block parameters 54 di function block parameters 57 integral lcd indicator 58 5. They can be constructed easily to the extent that existing pipes in a process can be con.
Magnetic flowmeters traditionally use more therefore magnetic flowmeter 4wire configuration as standard because cannot deliver enough current now that concept is with yokogawas admag axr supreme performance is realized admag axr is the current to achieve higher performance. For forward and reverse flow measurement functions, the totalized values of the flow direction forward or reverse and the flow direction are displayed on the indicator together with the units. Instructions are included with the installation manual on how to best ground the magnetic flow meter. However, yokogawa s digitalyewflo vortex flow meter had limited functions in tracking pressure changes especially in the measurement of gas and steam, for which mass flow measurement is. Digital stainless steel yokogawa magnetic flow meter, for. Moreover, the enhanced dual frequency excitation has. The axf magnetic flowmeter series are sophisticated products with outstanding reliability and ease of operation, developed on the basis of decades of field. It is a closely held company owned and operated by erik and lars rosaen. According to this principle, when a conductive medium passes through a magnetic field b, a. The fmg600 series electromagnetic flow meters are designed for measurement of conductive liquids. Yokogawa admag axf series user manual pdf download. However, if any errors or omissions are found, please inform yokogawa. Yokogawa admag axf magnetic flow meter axf250cnnap1lca112nbff1 free ship. Yokogawa axfa14g magnetic flowmeters axfa14g description yokogawa axfa14g magnetic flowmeters axfa14g yokogawa s magnetic flowmeter is supported by a long history of more than half a century.
The axf product lineup was developed in response to the. Axf magnetic flowmeter integral flowmeter yokogawa. The magnetic flowmeter must be installed within the specification conditions. All reasonable effort has been made to ensure the accuracy of the contents of this manual. Yokogawa yf104 yfa11 yewflo vortex flow meter assembly 112in 24v.
Moreover, the enhanced dual frequency excitation has been newly added to tackle more severe applications. Admag ca magnetic flow meters contro valve best valves. This manual describes the hardware configura tion of integral flowmeter and remote flowtube of the axf magnetic flowmeters. In faradays equation the k factor related the output to the induced emf. Download product documentation print product page add to request moreover, the enhanced dual frequency excitation has been newly added to tackle more severe applications. Magnetic flowmeter sizing flowmeter sizing because of its effect on flow velocity, sensor size is an important consideration. Yokogawa makes no warranty of any kind with regard to this material, including, but not limited to. Magnetic flowmeter sizing selecting the proper magmeter size the proper size of a magmeter is an important issue in terms of performance and longevity. Electromagnetic flow meters sensors and sensing equipment. They are able to log data quickly to internal memory, as. Data sheet electromagnetic flowmeter magmaster water. The axf magnetic flowmeters are sophisticated products with outstanding reliability and ease of operation, developed on the basis of decades of field proven experience. Users manual models ae100, ae200 and ae300 integral type.
Tds 3032a00 september 1995 magnetic flowmeter fundamentals. Magnetic flowmeters yokogawa admag axg wiratama mitra abadi flow meter 4122018 10. A magnetic flow meter mag meter, electromagnetic flow meter is a transducer that measures fluid flow by the voltage induced across the liquid by its flow through a magnetic field. Portable and handheld test instruments are part of every field technician or engineers toolkit. Admag axf magnetic flow meters contro valve best valves. Magnetic flow meters works based on faradays law of electromagnetic induction. Yokogawa axfa14g magnetic flowmeters axfa14g description yokogawa axfa14g magnetic flowmeters axfa14g yokogawas magnetic flowmeter is supported by a long history of more than half a century. Note for details of the axfa11g magnetic flowmeter converter, see the im01e20c0101e instruction manual.
1186 1550 1589 452 467 358 255 774 159 143 579 115 907 620 956 284 681 1125 562 659 828 702 762 437 1327 1260 720 1653 810 500 1041 154 362 74 154 1092 894 1311 86 732 1086 746 898 67 9 913 387